Human Lab Hospital
Old Busstand , Sunamganj Sadar, Sunamganj. Sylhet.

Project Key Specifications

Official engineering contract parameters & execution scope

Active Execution
Project Title

Human Lab Hospital

Engineering Category

Hospital Projects.

Facility Location

Old Busstand , Sunamganj Sadar, Sunamganj. Sylhet.

Execution Scope & Engineering Deliverables
Design Drawing of Fire Safety Plan/ NOC consist with below design : a) Master Plan Drawing of Fire Protection Layout including of all Building Structural Details. b) All Building Fire Protection Systems Drawing. c) All Building Fire Detection Systems Drawing. Refuge Area Drawing. d) Lightning Protection Systems (LPS) . e) Pump Room & Reservoir Details . f) Schematic Diagram of Fire Hydrant /Protection Systems. g) Gas Suppression Systems Design of Utility Building. h) SLD (Single Line Diagram) of Substation. i) Fire Separation Drawing. j) Evacuation Plan Drawing. k) Mechanical Ventilation Drawing of Basemen l ) Booklet Development : a. information with current front View of Building, b. Substation, Transformer, LT/HT Panel ,PFI panel, Generator, Broiler Technical Datasheet with Picture, c. Total Fire Systems Equipment Qty. & Technical Specification d. Maintenance Team full Information . e. Guideline For Fire Safety Issue & Approval from Fire Service & civil Defense .

Project Overview & Execution Scope

Comprehensive engineering consultancy and deployment details

Design Drawing of Fire Safety Plan/ NOC consist with below design : a) Master Plan Drawing of Fire Protection Layout including of all Building Structural Details. b) All Building Fire Protection Systems Drawing. c) All Building Fire Detection Systems Drawing. Refuge Area Drawing. d) Lightning Protection Systems (LPS) . e) Pump Room & Reservoir Details . f) Schematic Diagram of Fire Hydrant /Protection Systems. g) Gas Suppression Systems Design of Utility Building. h) SLD (Single Line Diagram) of Substation. i) Fire Separation Drawing. j) Evacuation Plan Drawing. k) Mechanical Ventilation Drawing of Basemen l ) Booklet Development : a. information with current front View of Building, b. Substation, Transformer, LT/HT Panel ,PFI panel, Generator, Broiler Technical Datasheet with Picture, c. Total Fire Systems Equipment Qty. & Technical Specification d. Maintenance Team full Information . e. Guideline For Fire Safety Issue & Approval from Fire Service & civil Defense .
Share Project Case Study:

Featured Showcase

Need Similar EPC Solutions?

Consult with our chartered engineers for BNBC-compliant fire protection, electrical audits, or smart BMS setups.

Visual Documentation

Project Photo Gallery